Dry hot high-temperature sterilization equipment

High Temperature Sterilizer Autoclave Machine 300W Nail Tool Sterilizer Dry Heat Sterilizer Dental Tool Sterilizer 1.5L Salon Equipment for Metal Tools with Handle

1、 Product parametersProduct Name: High Temperature Furnace/High Temperature Sterilizer/Dry Heat High Temperature Sterilization EquipmentCapacity: 1.5LInstallation method: desktopBrand: OtherAppearance: RectangularWorking mode: electric heating+temperature control (mechanical knob: one controls temperature, one controls time), mainly achieved through high-temperature dry and hot air sterilization.Working time: ≥ 30 minutesPower supply voltage: 110-240VRated power: 300WRated voltage: 110V~240V, 50/60HzTemperature range: 50-220 ℃…

Dry hot high-temperature sterilization equipment

High Temperature with Timer

Nail Tools Sterilizer】The temperature can be adjusted between 0°C and 220°C. When it reaches the maximum temperature, the power will automatically shut off.And You can set the time you need easy.

Widly Use

disinfection machine】The dry heat box can clean nail tools, tweezers, nail clippers, barber tools and other metal items. Different items can be adjusted to different temperatures to achieve good results.

Dry hot high-temperature sterilization equipment
Dry hot high-temperature sterilization equipment

Applicable scenarios

autoclave】It’s a perfect assistant for beauty salon, nail salon, pedicure, barber store, dental clinic or home use. The large capacity dry heat box allows you to clean more things at once, saving time and power.

Dry hot high-temperature sterilization equipment

High-quality and durable

disinfection box】Made of iron and stainless steel, the dry heat cabinet is sturdy and durable to carry high and low temperatures.The bottom is equipped with a protective tripod, which can be stably placed anywhere.The capacity of this box is 1.5L.

Usage Notes

disinfection box】Please check if the protective film inside the machine is clean before using it。

Dry hot high-temperature sterilization equipment
Dry hot high-temperature sterilization equipment

Guarantee Service

disinfection sterilization】We provide one year warranty of all our products.If there is any problems with your order, please feel free to contact our after-sales staff.

1、 Product parameters
Product Name: High Temperature Furnace/High Temperature Sterilizer/Dry Heat High Temperature Sterilization Equipment
Capacity: 1.5L
Installation method: desktop
Brand: Other
Appearance: Rectangular
Working mode: electric heating+temperature control (mechanical knob: one controls temperature, one controls time), mainly achieved through high-temperature dry and hot air sterilization.
Working time: ≥ 30 minutes
Power supply voltage: 110-240V
Rated power: 300W
Rated voltage: 110V~240V, 50/60Hz
Temperature range: 50-220 ℃ (can be heated 1-2 hours in advance, easy to use.)
Origin: Foshan City, Guangdong Province
Net weight: 3KG
Gross weight: 3.35KG
Panel Material: Metal Spray Paint
Inner liner material: stainless steel
Product size: 17.8 * 30.7 * 13CM
Packaging size: 36 * 21.6 * 18.4cm
Control mode: mechanical control/microcomputer touch control
Washing method: wiping
Opening and closing method: upward opening
Colors: black, white, beige, orange, green (colors can be customized for large quantities)
Product List: Host * 1+Power Cord * 1+Instruction Manual * 1
Applicable scenarios: Disinfection and sterilization of metal tools in tattoo shops, earring shops, ear picking shops, etc.
Applicable products: Metal products, capable of withstanding high temperatures.
Packing quantity: 6PCS
Packing size: 44.5 * 38.5 * 58cm
Packing weight: 15.5 kg
Display mode: None
Functional difference: None
Common heating and disinfection items:
-Disinfection: Metal jewelry, keys, tattoo tools, ear picking tools, etc
Power cord: 1.2 meters
Sealing instructions: None.

2、 Usage method

  1. Preparation before operation
    ——》Cleaning equipment: Ensure that there are no stains or residues inside the cabinet, and check the sealing of the door seal (to avoid heat leakage).
    Pre treatment of items: Clean and dry the items to be sterilized (to avoid moisture evaporation affecting the sterilization effect), and ensure that the items are resistant to dry heat and high temperature.
    ——》Loading items: Place the items evenly on the shelf, avoiding overlap or obstruction (ensuring hot air circulation), and not touching the cabinet wall (preventing local overheating).
  2. Running operations
    ——》Set parameters: Use the knob to set the target temperature (such as 160 ℃) and time (such as 2 hours).
    ——》Start the device: Press the power button to start heating up the device, and the green light indicates that it is running; A red light is usually a fault/overheating warning.
    ——》Process monitoring: Do not open the cabinet door during operation (to avoid high temperature burns and temperature drops affecting sterilization). After the time is up, the equipment will automatically stop heating.
  3. Post sterilization treatment
    ——》Cooling: Wait until the temperature inside the cabinet drops below 60 ℃ (to avoid burns and damage from thermal expansion and contraction of items), then open the cabinet door.
    ——》Retrieve items: Wear insulated gloves to retrieve items, ensure they are dry, and store them in a sterile container/environment.
    ——》Equipment cleaning: Use a dry cloth to wipe the cabinet and keep it dry (to avoid residual moisture from rusting the equipment).

4、 Applicable items
Only applicable to items that are resistant to high temperatures, dry heat, and moisture, including:
——》Metal products: stainless steel scissors, tweezers, surgical knives, dental instruments, nail tools, etc.
——》Glass products: glass test tubes, culture dishes, beakers, thermometers (glass models), etc.
——》Ceramics: ceramic vessels, high-temperature resistant beauty tool bases, etc.
——》High temperature resistant plastics: Some high temperature resistant appliances made of PTFE and PP materials (need to confirm that the material has a temperature resistance of ≥ 120 ℃).
❌ Prohibited items:
Plastics that are not resistant to high temperatures (such as ordinary PP and PE, will deform/release harmful substances).
Flammable/explosive materials (such as alcohol swabs, oils and fats).
Items that are damp/have moisture (can affect sterilization effectiveness and may cause rusting inside the cabinet).
Rubber and leather (will age and deform at high temperatures).

5、 Applicable scenarios
This device is a “mini type” suitable for sterilization of small batches and small items. The main scenarios include:
——》Beauty/nail art/SPA institutions: disinfect beauty tools (such as scissors, tweezers, nail art equipment).
——》Small medical institutions/clinics: disinfection dental instruments, acupuncture and moxibustion needles, small surgical tools (non implantable).
——》Laboratory/Research Scenario: Disinfect glassware (test tubes, culture dishes), metal experimental tools.
——》Home/Small Studio: Disinfect and heat-resistant personal care tools (such as razors and scissors).

6、 Introduction to Working Principle
-The core is the dry heat sterilization method: the air inside the cabinet is heated to 120-180 ℃ by built-in heating elements (such as electric heating wires/far-infrared heating tubes), and the oxidation effect and protein denaturation mechanism of high-temperature dry heat air are used to destroy the cell structure of microorganisms (including bacteria, viruses, spores), making them inactive, thus achieving the sterilization effect.
The higher the temperature, the shorter the sterilization time: usually 160 ℃ needs to last for 2 hours, and 180 ℃ needs to last for 30 minutes (depending on the equipment parameters).
Features: No moisture, no steam, sterilized items are dry, suitable for items that are sensitive to moisture.

7、 Detailed explanation of working principle