Nail Tools Cleaner High temperature Pot for Scissors Tweezers Clippers Nail Art Tools Manicure Cleaning Clean Box for Nail&Hair Salon
1、 Product parameters Product Name: Small High Temperature Dry Heat Disinfection Device (Glass Bead Disinfection Type)/Mini Small Scissor Cup/Disinfection Cup/Vertical High Temperature Furnace/High Temperature Sterilizer/Dry Heat High Temperature Sterilization EquipmentApplicable scenarios: nail salons, hair salons, beauty salons, dental/medical beauty clinicsDisinfection objects: metal tools such as scissors, tweezers, needles, etcDisinfection method: High temperature dry heat (glass…





1、 Product parameters
Product Name: Small High Temperature Dry Heat Disinfection Device (Glass Bead Disinfection Type)/Mini Small Scissor Cup/Disinfection Cup/Vertical High Temperature Furnace/High Temperature Sterilizer/Dry Heat High Temperature Sterilization Equipment
Applicable scenarios: nail salons, hair salons, beauty salons, dental/medical beauty clinics
Disinfection objects: metal tools such as scissors, tweezers, needles, etc
Disinfection method: High temperature dry heat (glass beads conduct heat)
Disinfection temperature range: 150 ℃~200 ℃ (some models can reach up to 250 ℃)
Disinfection time: 5-30 minutes (adjusted according to different tool types)
Rated voltage: 220V/110V
Rated power: 75W (regular model)
Temperature control method: mechanical constant temperature (automatic temperature control)
Inner liner material: Aluminum alloy (thermal conductive inner liner)
Inner container capacity: approximately 220ml (can hold 5-8 tools)
Inner container size: diameter about 5cm x depth about 8cm
Product dimensions: diameter 16cm x height 15cm
Net weight: approximately 1.5kg
Gross weight: approximately 2kg
Standard accessories: disinfectant glass beads (approximately 150g), power plug
Safety design: Over temperature protection, bottom anti slip
Appearance material: ABS plastic shell (white)
Capacity: 150 milliliters
Installation method: Vertical
Brand: Other
Appearance: Vertical circular body (switch located at the bottom)
Working mode: electric heating+heating wire temperature control (mechanical switch)
Working time: ≥ 30 minutes
Power supply voltage: 110-240V
Rated power: 100W
Rated voltage: 110V~240V, 50/60Hz
Temperature range: 50-220 ℃ (can be heated 1-2 hours in advance, easy to use.)
Origin: Foshan City, Guangdong Province
Net weight: 0.45KG
Gross weight: 0.5KG
Panel material: ABS plastic
Inner liner material: Aluminum alloy
Product size: 16 * 16 * 16CM
Packaging size: 17 * 17 * 17CM
Control mode: mechanical control/microcomputer touch control
Washing method: wiping
Opening and closing method: upward opening
Color: White, Blue, Purple, Yellow, Black (customizable for large quantities)
Product List: Host * 1+Power Cord * 1+Instruction Manual * 1
Applicable scenarios: Disinfection and sterilization of metal tools in tattoo shops, earring shops, ear picking shops, etc.
Applicable products: Metal products, items that can withstand high temperatures.
Packing quantity: 12PCS
Packing size: 49.5 * 34 * 35cm
Packing weight: 8 kg
Display mode: None
Functional difference: None
Common heating and disinfection items:
-Disinfection: Metal jewelry, keys, tattoo tools, ear picking tools, etc
Power cord: 1.2 meters
Sealing instructions: None.
2、 Usage method
- Preparation stage
-Tool pretreatment: Clean the surface stains, residual glue (nail polish glue), etc. of the metal tools (such as scissors and tweezers) to be disinfected (to avoid sticking to the inner liner after high-temperature carbonization), and use an alcohol swab to simply wipe the surface dust.
-Disinfection bead filling: Open the top cover of the sterilizer and pour the matching glass disinfection beads into the inner container, filling it to 80% of the container capacity (about 150g), ensuring that the tool can be completely buried by the beads after insertion (ensuring even heat conduction).
-Power on inspection: Connect the power plug to the socket of the corresponding voltage (220V/110V needs to be matched), press the red power switch, and observe whether the green indicator light is on (it indicates the start of heating). - Disinfection operation
-Tool insertion: After the sterilizer is heated for 10 minutes (temperature stabilizes above 150 ℃), use tweezers to slowly insert the pre treated tool into the inner container, ensuring that the tool is completely submerged in the glass beads.
-Disinfection duration control:
Small tools (such as dead skin scissors, needles): 5-10 minutes (can kill common pathogenic bacteria such as Escherichia coli and Staphylococcus aureus at 150 ℃);
-Larger tools (such as hair scissors): 15-20 minutes (ensure that the internal gaps of the tool are fully heated);
-High risk tools (such as medical beauty needles): 25-30 minutes (can inactivate viruses and spore like microorganisms at 200 ℃).
-Remove tools: After disinfection is complete, turn off the power and wait for 2-3 minutes (to avoid overheating and hot hands). Use specialized tweezers to remove the tools and place them on a sterile tray for later use. - Subsequent maintenance
-Disinfection bead cleaning: Pour out the glass beads every week, rinse them with clean water, and air dry them to remove impurities on the surface of the beads (if the beads change color or shatter, they need to be replaced in a timely manner);
-Inner liner cleaning: Wipe the inner liner with a dry soft cloth every month to avoid residual foreign objects affecting heat conduction;
-Storage requirements: After use, disconnect the power supply. After the body has completely cooled down, place it in a dry and ventilated environment (to avoid moisture causing internal components to rust).
4、 Applicable items
- Applicable items (core)
Nail tools: dead skin clipper, nail clipper, polishing strip (metal version), skin pushing steel pusher;
Hairdressing tools: scissors, razor (metal blade), comb (metal material);
Small medical/cosmetic tools: tweezers (medical), embroidery needles, blood collection needles, earring gun needles, etc. - Restricted items (strictly prohibited from being placed)
Non metallic material tools: plastic, wood, resin tools (high temperature can cause deformation and melting);
Tools with rubber/silicone components: such as scissors with silicone handles (rubber will age at high temperatures);
Flammable and explosive materials: tools containing alcohol and essential oils (high temperatures may cause combustion);
Precision electronic tools: such as electric nail clippers (high temperatures can damage the circuit).
5、 Applicable scenarios
- Business scenarios
Nail/eyelash salon: used for daily tool disinfection, in accordance with the requirements of “one customer, one disinfection for public supplies and appliances” in the “Hygiene Standards for Beauty and Hairdressing Venues”, to avoid cross infection;
Barbershops: Disinfect tools that come into direct contact with the skin, such as scissors and razors, to reduce the risk of spreading diseases such as folliculitis and psoriasis;
Medical beauty/embroidery institutions: meet the standard of “medium level disinfection for low-risk instruments (such as tweezers)” in the “Technical Specifications for Disinfection of Medical Institutions”, and adapt to the rapid disinfection needs of small instruments;
Pet Shop: Used for disinfecting pet grooming tools (such as pet nail clippers) to prevent cross infection of bacteria between pets. - Family scene
Personal nail tool disinfection: suitable for nail enthusiasts to clean their personal tools on a daily basis, especially for households where multiple people share tools;
Disinfection of mother and baby tools: Disinfection of small metal tools such as baby nail clippers and nasal tweezers (note to lower the temperature to below 150 ℃).
6、 Introduction to Working Principle
The core of this sterilizer is high-temperature dry heat sterilization technology, relying on “glass bead thermal conductivity+constant temperature control” to achieve efficient disinfection:
Thermal conduction logic: After being powered on, the heating element (PTC ceramic heating element) at the bottom of the sterilizer generates heat, which is transferred to the glass beads through the aluminum alloy liner; Glass beads, due to their small specific heat capacity and fast thermal conductivity, can quickly heat up to the set temperature (150 ℃~200 ℃) and evenly wrap the tool immersed in the heat.
-Sterilization principle: Under high temperature environment, the proteins of microorganisms (bacteria, viruses, spores) will undergo denaturation and coagulation, and the cell membrane structure will be destroyed, thereby losing activity; 150 ℃ for 5 minutes can kill 99.9% of common pathogenic bacteria, and 200 ℃ for 20 minutes can inactivate spores (such as Bacillus subtilis).
-Temperature control mechanism: Equipped with a bimetallic thermostat, when the temperature inside the container reaches the set value, the thermostat automatically disconnects the circuit and stops heating; After the temperature drops, the thermostat closes again to maintain the stable temperature of the inner container within the disinfection range, ensuring disinfection effectiveness and avoiding energy waste.
【Recommended Related Products 】
UV sterilizer
disinfection cabinet
High Temperature Sterilizer
Hot Stones Massage Heater
Hot Towel Cabinets
Massage Oil Warmer